What winter here does to a heat pump
Your furnace, if you have one, runs from October through May, about eight months a year. That's the season that matters most in this decision, because it's the longer one and the harder one. The overnight low here averages 17°F across December, January and February, and it drops to freezing or below on about 150 nights a year. Those are the nights a heat pump has to work hardest, and they're also the nights it works worst.
A standard heat pump starts losing ground below 40°F, putting out less heat than its rating says it should. Below about 35°F it typically needs backup heat to fill the gap. Your winter low here sits below both marks, and every single one of those 150 freezing nights is below both marks too. That's not a cold snap a few times a year. That's most of the heating season.
There's a real answer to this, which is a cold-climate heat pump. To earn that label a unit has to prove, in third-party testing, that it still makes at least 1.75 units of heat per unit of electricity at 5°F and holds onto 70 percent of its 47°F capacity at that temperature. Field tests of prototype cold-climate units back this up: backup heat covered only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. The federal-minimum heat pump priced in the running-cost band above isn't that unit. If you're looking at a heat pump for this county, the cold-climate rating is what you're actually shopping for, not the standard one.